Where to put the fuses

A fuse protects the wire that leaves a power source. A solar system has three: the panels, the batteries and the generator. Here's where each fuse and each switch goes, with a diagram.

Tap a part to see its guide

The golden rule

Every wire that leaves a power source gets its fuse, on the source side. The most dangerous is the battery: in a short circuit, it can deliver thousands of amps at once.

The whole system

The diagram shows only the positive (+) wire, where the fuses go. Each number is explained below.

PanelsMPPT controllerBatteries+ bus barInverter-charger120 V paneland outlets12 V fuse blockGenerator12345678+ wirefuse or breakerswitch (disconnect)
  1. 1

    Between the panels and the controller

    A disconnect to cut off the panels during work (even in the sun, they give current). With three or more strings in parallel, a fuse on each string.

    Size: String fuse: the “maximum series fuse” value on the panel's label.

  2. 2

    Between the controller and the battery

    A fuse or a breaker rated for direct current (DC), on the battery or + bus bar side.

    Size: The controller's output current × 1.25 (a 40 A controller: 50 A fuse).

  3. 3

    The battery fuse

    The most important one. Right on the battery's +, or within 18 cm. It must be able to cut a very big short circuit: a class T fuse or a terminal-mounted fuse (MRBF).

    Size: Based on the biggest wire leaving the battery and the total of what's connected.

  4. 4

    The main switch

    A battery disconnect to cut everything at once: maintenance, work, or if something heats up.

    Size: At least the battery fuse's current.

  5. 5

    Between the + bus bar and the inverter

    A fuse just for the inverter, near the + bus bar. It's often the biggest current in the system.

    Size: Inverter watts ÷ voltage ÷ 0.9 × 1.25 (2,000 W at 12 V: about 250 A).

  6. 6

    The 12 V fuse block

    Each DC circuit (lights, pump, fan, 12 V fridge) gets its own small fuse, chosen for its wire.

    Size: Based on each circuit's wire: see the wire tool.

  7. 7

    The inverter's 120 V output

    A real breaker panel, like in a house, with shock protection (GFCI) where the code requires it. That's an electrician's job.

    Size: Per your country's electrical code.

  8. 8

    The generator input

    The generator's breaker protects the wire to the inverter-charger. Never plug a generator into a household outlet.

    Size: Based on the generator and the wire to the inverter-charger.

Two details that matter

+−BatteryFuse≤ 18 cm
The fuse right at the batteryThe longer the wire before the fuse, the more wire is unprotected. Keep it as short as possible.
String 1String 2String 3CombinerboxController
One fuse per stringIf one string shorts, the other strings discharge into it. Each string's fuse prevents that.

Words to know

DC fuse
Made for direct current. A fuse or breaker made for 120 V household power doesn't cut a DC arc well.
Interrupt rating
The biggest current a fuse can cut without blowing apart. A lithium battery can exceed 10,000 A in a short circuit.
Class T
A fuse with a very high interrupt rating, made for the output of big batteries.
Bus bar
A copper bar where all the + wires (or all the −) connect. Cleaner and safer than stacking lugs on the battery.
Disconnect
A switch made to cut a big direct current by hand.

Classic traps

  • Putting the fuse at the far end of the wire, near the device: all the wire between the battery and the fuse stays unprotected.
  • Using an AC (household) breaker on a battery circuit: it may not cut the arc.
  • Stacking five lugs on the battery terminal: use a bus bar.
  • Forgetting the negative wire: it must be as big as the positive. It has no fuse, but it often goes through a shunt (the battery monitor's sensor).

To calculate

Next step

You've covered every part. The calculator puts it all together for your project, with real weather for the spot.